Supply · Andaman and Nicobar Islands
Power Transformers in Andaman and Nicobar Islands
1 – 20 MVA. Delivery across Andaman and Nicobar Islands about 11 days by road, built to the specification your utility or project issues.

Power transformer under assembly
Logistics and network
Supplying Andaman and Nicobar Islands.
Deliveries across Andaman and Nicobar Islands start at about 3210 km by road, which puts the nearer cities (Port Blair) within 11 days of dispatch. The state's demand centres on Port Blair, island diesel and solar grids, shipping.
Distribution in Andaman and Nicobar Islands is handled by Electricity Department, Andaman and Nicobar; Electricity Department runs the transmission network. Programmes now in execution include Island solar and submarine cable programmes, and each is tendered against a technical specification that we quote and manufacture to.
The power transformer line closed the last gap in the chain. Between distribution and power class we now cover 16 kVA right through to 20 MVA — a span very few regional manufacturers hold on a single site.
The standard substation build is 33/11 kV, Dyn11, ONAN, with an off-circuit tap changer at +5% to −10%. Where the network needs voltage regulation under load we fit an on-load tap changer at +5% to −15%, and where the load profile justifies forced cooling we supply ONAF with a rated output at each cooling stage.
| Parameter | Specification |
|---|---|
| Rated power | 1 MVA to 20 MVA |
| Typical ratings | 1 · 1.6 · 2 · 2.5 · 3.15 · 5 · 6.3 · 8 · 10 · 12.5 · 16 · 20 MVA |
| Voltage class | 33 / 11 kV; highest system voltage 36 kV |
| Phases | Three-phase |
| Type | Oil-immersed, outdoor, core type — plain or corrugated tank; dry type to order |
| Frequency | 50 Hz standard; 60 Hz for export |
Specifying
What changes for Andaman and Nicobar Islands.
- Design ambient 40 °C humid; seismic classification Zone V for structures and foundations.
- Coastal and industrial exposure: C5-M grade exterior paint, stainless or hot-dip galvanized hardware and heavier zinc coating on steel parts for sites near the coast.
- Temperature rise 45 K winding and 40 K top oil over the stated ambient, or 55 K / 50 K where Electricity Department specifications allow; losses, impedance and tapping to the utility schedule or IS 1180 level.
Questions
Frequently asked.
How long does delivery of Power Transformers to Andaman and Nicobar Islands take?
Can you build to the Electricity Department specification?
Do you supply private buyers and contractors across Andaman and Nicobar Islands, not only utilities?
Also for Andaman and Nicobar Islands
Send us your Power Transformers schedule for Andaman and Nicobar Islands.
Ratings, quantities, the specification you are buying against and the delivery point. We return a quotation with a firm delivery programme.