Aggarwal GlobalEmpowering Nation Enquire

2,500 t / month

Lattice Towers & Structures

Lattice transmission towers, M-type towers and substation structures — cut, punched, formed, assembled and hot dip galvanized entirely in-house at 2,500 tonnes a month.

Output2,500 tonnes a month
TypesLattice, M-type, substation
FinishHot dip galvanized
Galvanized tower sections leaving the shed

Galvanized tower sections leaving the shed

01

Overview

2,500 ton / month

Sustained fabrication and galvanizing output.

Galvanized in-house

No third-party coating queue in the delivery programme.

To your drawings

Fabrication against the purchaser's drawings and BOM.

Steel in, galvanized tower out.

Tower fabrication and galvanizing sit side by side on the campus. Sections are cut, punched, formed and assembled in our own shop, then go straight into our own zinc bath rather than travelling to a third-party galvanizer and back.

That single decision removes the longest and least predictable step in most tower supply chains. It is also why we can hold 2,500 tonnes a month without the coating queue that constrains fabricators who buy galvanizing in.

02

Technical data

Specification.

Built to the purchaser's schedule. Fields marked On enquiry are issued against a specific enquiry. Delivery as per the client's requirement, confirmed with the quotation. Open the rows below for construction details, reference tables and fittings.

General

ParameterSpecification
ProductsLattice transmission towers, M-type towers, substation gantries and equipment structures
Standard height12.8 metres and various sizes to drawing
FabricationCutting, punching, drilling, notching, forming and assembly in-house
GalvanizingHot dip, in-house — bath up to 1 m × 7.25 m
Monthly capacity2,500 tonnes
Steel gradeIS 2062 structural steel — grade to drawing

Coating

ParameterSpecification
StandardIS 4759:1996 coating mass; ISO 1461:2009 where specified
Coating mass, steel 5 mm and above610 g/m² minimum
Coating mass, steel 2 to 5 mm460 g/m² minimum
Uniformity testIS 2633 — four one-minute copper sulphate dips
Adhesion testIS 2629 — pivoted hammer and knife test
FastenersGalvanized to IS 1367
Reference data — what the standards requireTables from the Indian Standard, for checking any quotation against it

Coating requirements

Minimum mass of zinc coating — IS 4759:1996 Table 1
Product classMinimum coating mass (g/m²)Indicative thickness (µm)
Grey iron and malleable iron castings610~86
Fabricated steel 5 mm thick and above610~86
Fabricated steel 2 to 5 mm thick460~65
Fabricated steel 1.2 to 2 mm thick340~48
Threaded work 10 mm diameter and above300~42
Threaded work under 10 mm diameter270~38

IS 4759 specifies coating mass, not thickness. The thickness column is a derived conversion at 7.14 g/m² per micron and is indicative only.

Coating requirements — ISO 1461:2009 Table 3, articles not centrifuged
Article and thicknessLocal thickness min (µm)Local mass min (g/m²)Mean thickness min (µm)Mean mass min (g/m²)
Steel above 6 mm7050585610
Steel above 3 up to 6 mm5539570505
Steel 1.5 to 3 mm4532555395
Steel under 1.5 mm3525045325
Castings 6 mm and above7050580575
Castings under 6 mm6043070505

For the heaviest class the two standards agree exactly: IS 4759's 610 g/m² for steel 5 mm and above equals ISO 1461's 610 g/m² mean for steel above 6 mm.

Standard and optional fittingsWhat is supplied as standard, and what is available to order

Scope

What we supply

  • Fabrication to purchaser drawings and bills of material
  • Lattice towers and M-type towers
  • Substation gantries and equipment structures
  • Cross-arms, brackets and line hardware
  • Fabricated steel items to specification
  • Hot dip galvanizing of all supplied steel
  • Trial assembly where specified
  • Bundling, marking and dispatch to site

Process

How a tower is built

  • Raw structural steel received and inspected
  • Cutting and shearing to section lengths
  • Punching, drilling and notching
  • Forming, bending and cleat assembly
  • Trial assembly where specified
  • Surface preparation and acid pickling
  • Hot dip galvanizing
  • Coating thickness check, bundling and marking
03

Compliance

Standards & testing.

Routine tests are performed on every unit before dispatch. Type tests are certified from CPRI, ERDA or NABL-accredited laboratories on request.

Standards we manufacture and test to
StandardScope
IS 2062Hot rolled medium and high tensile structural steel
IS 4759:1996Hot dip zinc coatings on structural steel and other allied products
IS 2629:1985Recommended practice for hot dip galvanizing of iron and steel
IS 2633:1986Testing uniformity of coating on zinc coated articles
IS 6745:1972Determination of mass of zinc coating
IS 1367Technical supply conditions for threaded steel fasteners
ISO 1461:2009Hot dip galvanized coatings on fabricated iron and steel articles
IEC 60652Loading tests on overhead line structures

Applications

Where it goes to work.

Transmission

Overhead lines

11 kV, 33 kV and higher transmission and distribution lines.

Substation

Structures

Gantries, equipment structures and support steelwork.

Utility

Rural electrification

Line construction under national electrification programmes.

Industry

Private networks

Captive lines for plant and industrial estate distribution.

FAQ

Questions

Frequently asked.

Do you galvanize the towers you fabricate?
Yes, in our own bath on the same site. That removes the third-party coating step that is usually the least predictable part of a tower delivery programme.
What is the largest section you can galvanize?
Our hot dip bath takes articles up to 1 m × 7.25 m. Larger articles are handled by progressive dipping where the geometry allows — ask us about your specific section.
Do you design towers or only fabricate them?
We fabricate to the purchaser's drawings and bill of material. Tower design and line design are normally carried out by the utility or its consultant.

Send your tower drawings.

Share the type schedule, tonnage and galvanizing specification, and we will price fabrication and coating together.