Supply · Dadra and Nagar Haveli and Daman and Diu
Distribution Transformers in Dadra and Nagar Haveli and Daman and Diu
16 kVA – 1000 kVA. Delivery across Dadra and Nagar Haveli and Daman and Diu about 5 days by road, built to the specification your utility or project issues.

Finished distribution transformers in the dispatch yard
Logistics and network
Supplying Dadra and Nagar Haveli and Daman and Diu.
Deliveries across Dadra and Nagar Haveli and Daman and Diu start at about 1240 km by road, which puts the nearer cities (Daman, Silvassa) within 5 days of dispatch. The state's demand centres on Silvassa and Daman industrial estates: plastics, textiles, engineering.
Distribution in Dadra and Nagar Haveli and Daman and Diu is handled by DNHDDPDCL; DNHDDPDCL runs the transmission network. Programmes now in execution include RDSS, and each is tendered against a technical specification that we quote and manufacture to.
Distribution transformers are the highest-volume line on the campus — around 900 jobs a month across the full IS 1180 rating ladder, from 16 kVA agricultural units to 1000 kVA industrial supply.
Standard build is Dyn11, ONAN, 11/0.433 kV or 33/0.433 kV, with off-circuit tapping. But almost nothing here is fixed: vector group, impedance, tapping range, winding material, fittings and efficiency level are all specified by the purchaser, and we build to that schedule rather than asking you to accept ours.
| Parameter | Specification |
|---|---|
| Rated capacity | 16 kVA to 1000 kVA (1 MVA) |
| Phases | Three-phase and single-phase |
| Type | Oil-immersed, outdoor — sealed corrugated-tank or conservator type; dry type (AN) for indoor duty |
| Voltage class | 11 kV, 22 kV and 33 kV systems |
| Standard voltage ratios | 11 / 0.433 kV · 22 / 0.433 kV · 33 / 0.433 kV · 11 / 0.25 kV single-phase |
| Frequency | 50 Hz standard; 60 Hz for export |
Specifying
What changes for Dadra and Nagar Haveli and Daman and Diu.
- Design ambient 45 °C humid; seismic classification Zone III for structures and foundations.
- Coastal and industrial exposure: C5-M grade exterior paint, stainless or hot-dip galvanized hardware and heavier zinc coating on steel parts for sites near the coast.
- Temperature rise 45 K winding and 40 K top oil over the stated ambient, or 55 K / 50 K where DNHDDPDCL specifications allow; losses, impedance and tapping to the utility schedule or IS 1180 level.
Questions
Frequently asked.
How long does delivery of Distribution Transformers to Dadra and Nagar Haveli and Daman and Diu take?
Can you build to the DNHDDPDCL specification?
Do you supply private buyers and contractors across Dadra and Nagar Haveli and Daman and Diu, not only utilities?
Also for Dadra and Nagar Haveli and Daman and Diu
Send us your Distribution Transformers schedule for Dadra and Nagar Haveli and Daman and Diu.
Ratings, quantities, the specification you are buying against and the delivery point. We return a quotation with a firm delivery programme.