Supply · Haryana
Power Transformers in Haryana
1 – 20 MVA. Delivery across Haryana about 2 days by road, built to the specification your utility or project issues.

Power transformer under assembly
Logistics and network
Supplying Haryana.
Deliveries across Haryana start at about 30 km by road, which puts the nearer cities (Bhiwani, Rohtak, Hisar) within 2 days of dispatch. The state's demand centres on Gurugram and Faridabad engineering and auto, Panipat refinery and textiles, Hisar steel, Bhiwani textiles, Yamunanagar plywood and metals, IMT Manesar, Bahadurgarh footwear.
Distribution in Haryana is handled by UHBVN and DHBVN; HVPNL runs the transmission network. Programmes now in execution include RDSS, HVPNL 33 kV substation programme, UHBVN and DHBVN feeder works, and each is tendered against a technical specification that we quote and manufacture to.
The power transformer line closed the last gap in the chain. Between distribution and power class we now cover 16 kVA right through to 20 MVA — a span very few regional manufacturers hold on a single site.
The standard substation build is 33/11 kV, Dyn11, ONAN, with an off-circuit tap changer at +5% to −10%. Where the network needs voltage regulation under load we fit an on-load tap changer at +5% to −15%, and where the load profile justifies forced cooling we supply ONAF with a rated output at each cooling stage.
| Parameter | Specification |
|---|---|
| Rated power | 1 MVA to 20 MVA |
| Typical ratings | 1 · 1.6 · 2 · 2.5 · 3.15 · 5 · 6.3 · 8 · 10 · 12.5 · 16 · 20 MVA |
| Voltage class | 33 / 11 kV; highest system voltage 36 kV |
| Phases | Three-phase |
| Type | Oil-immersed, outdoor, core type — plain or corrugated tank; dry type to order |
| Frequency | 50 Hz standard; 60 Hz for export |
Specifying
What changes for Haryana.
- Design ambient 50 °C; seismic classification Zone IV for structures and foundations.
- Inland exposure: standard epoxy-polyurethane exterior finish and hot-dip galvanized steel parts.
- Temperature rise 45 K winding and 40 K top oil over the stated ambient, or 55 K / 50 K where UHBVN and DHBVN specifications allow; losses, impedance and tapping to the utility schedule or IS 1180 level.
Questions
Frequently asked.
How long does delivery of Power Transformers to Haryana take?
Can you build to the UHBVN and DHBVN specification?
Do you supply private buyers and contractors across Haryana, not only utilities?
Send us your Power Transformers schedule for Haryana.
Ratings, quantities, the specification you are buying against and the delivery point. We return a quotation with a firm delivery programme.