Supply · United Arab Emirates
Solar & Inverter Duty Transformers in United Arab Emirates
Up to 20 MVA. Manufactured in India to IS and IEC standards and shipped to United Arab Emirates: Ex Factory or FOB Mundra / Nhava Sheva.

Tanks awaiting core-and-coil assembly
Logistics and network
Shipping to United Arab Emirates.
Consignments for United Arab Emirates move Sea from Mundra or Nhava Sheva to Jebel Ali, then road to any emirate. Typical transit is 3 to 5 days; discharge at Jebel Ali (Dubai), Khalifa Port (Abu Dhabi). We quote Ex Factory or FOB Mundra / Nhava Sheva, with payment by LC at sight or advance, USD or AED.
The grid runs at 50 Hz with 400/230 V low-voltage supply and 11 kV and 33 kV distribution (22 kV in parts of Abu Dhabi); 132 kV and above transmission. Distribution is operated by DEWA (Dubai), ADDC and TRANSCO (Abu Dhabi), SEWA (Sharjah), EtihadWE (northern emirates), regulated by Emirate-level regulators and the Ministry of Energy and Infrastructure. Import conformity: ESMA / MoIAT ECAS applies to low-voltage equipment up to 1,000 V; medium-voltage equipment is accepted against utility specifications and type-test certificates (DEWA, ADDC, SEWA).
The product
A solar transformer is not a distribution transformer with a different label.
An inverter feeds the transformer a non-sinusoidal current with significant harmonic content, and it does so on a duty cycle that is de-energised for roughly half the year. Both facts change the design.
Harmonic currents drive eddy-current heating in the windings that a standard design does not allow for, so conductors are transposed and the core flux density is de-rated to leave headroom. The overnight de-energised period means no-load loss dominates lifetime energy cost far more than it does on a distribution feeder — which is why the low-no-load-loss design is worth paying for here and not always elsewhere.
| Parameter | Specification |
|---|---|
| Rated power | Up to 20 MVA |
| HV voltage | 11 kV or 33 kV |
| LV voltage | 315 / 380 / 415 / 480 / 600 / 690 / 800 V — the inverter output, not 433 V |
| Winding arrangement | Two, three or more secondaries; dual secondary is the norm |
| Duty | Step-up, outdoor, solar or wind generation |
| Frequency | 50 Hz standard; 60 Hz for export |
Specifying
What changes for United Arab Emirates.
- Climate and site: Desert, design ambient 50 °C and above, high humidity on the coast, dust.
- Built to IEC 60076 for 50 Hz, with insulation levels for the 11 kV and 33 kV distribution (22 kV in parts of Abu Dhabi) and 400/230 V secondaries; temperature-rise limits and cooling sized for the stated ambient and altitude.
- Fittings, bushings and tap-changer ranges follow the utility specification (DEWA (Dubai), ADDC and TRANSCO (Abu Dhabi), SEWA (Sharjah), EtihadWE (northern emirates)); type-test certificates from CPRI or ERDA accompany the offer.
- Documentation: commercial invoice, packing list, certificate of origin, test certificates and the import conformity certificate where United Arab Emirates requires one.
Questions
Frequently asked.
How long does delivery of Solar & Inverter Duty Transformers to United Arab Emirates take?
What documents and certificates come with a consignment to United Arab Emirates?
Which standard and voltage class do you build to for United Arab Emirates?
Also for United Arab Emirates
Send us your Solar & Inverter Duty Transformers schedule for United Arab Emirates.
Ratings, quantities, the specification you are buying against and the delivery point. We return a quotation with a firm delivery programme.