Squirrel to Goat. Manufactured in India to IS and IEC standards and shipped to Ethiopia: Ex Factory or FOB Mundra / Nhava Sheva; CIF Djibouti on request.

RangeSquirrel to Goat
Delivery8 to 12 days to Djibouti, 3 to 5 days road
StandardIS 398 (Part 2):1996
Stranding machine in the conductor hall

Stranding machine in the conductor hall

01

Logistics and network

Shipping to Ethiopia.

Consignments for Ethiopia move Sea to Djibouti (Doraleh), then road to Addis Ababa, about 900 km. Typical transit is 8 to 12 days to Djibouti, 3 to 5 days road; discharge at Djibouti (Doraleh), then road. We quote Ex Factory or FOB Mundra / Nhava Sheva; CIF Djibouti on request, with payment by LC at sight or advance, USD.

The grid runs at 50 Hz with 380/220 V low-voltage supply and 15 kV and 33 kV distribution (EEU reports over 54,000 km of 15/33 kV lines); 132 kV, 230 kV and 400 kV transmission. Distribution is operated by Ethiopian Electric Utility (EEU) for distribution and Ethiopian Electric Power (EEP) for generation and transmission, regulated by Ethiopian Petroleum and Energy Authority. Import conformity: ECAE Pre-Export Verification of Conformity: Certificate of Conformity valid six months, issued by an ECAE-authorised body; local inspection and testing for uncertified consignments.

02

The product

The line between the towers.

Full specification and gallery

ACSR is the workhorse of Indian overhead distribution and transmission. It is also one of the two products that lets us quote a complete line package — tower, conductor, pole and transformer — rather than a part of one.

The table below is the IS 398 (Part 2) basis we manufacture and test against. One caution worth stating plainly: IS 398 Part 5 publishes the same codewords with resistance around 2–3% lower and breaking loads 2–3% higher. Mixing rows from the two parts is the easiest way for a utility QA engineer to catch an error, so we quote Part 2 throughout and say so.

ParameterSpecification
ProductAluminium Conductor Steel Reinforced (ACSR)
StandardIS 398 (Part 2):1996; IEC 61089 for export
CodewordsSquirrel, Gopher, Weasel, Ferret, Rabbit, Mink, Beaver, Raccoon, Cat, Dog, Dingo, Wolf, Lynx, Panther, Bear, Goat
AluminiumEC grade aluminium wire, high UTS
Steel coreGalvanized steel wire
Monthly capacity1,500 km
03

Specifying

What changes for Ethiopia.

  • Climate and site: Addis Ababa and the highlands at 2,000 to 2,500 m, altitude derating of insulation and cooling; hot lowlands at Dire Dawa.
  • ACSR to IEC 61089 or IS 398 as the specification requires, with galvanized steel core to IS 4826 and heavier zinc coating for coastal lines.
  • Drum lengths and drum type to the stringing contractor's requirement; conductor data sheets issued in the utility's format.
  • Documentation: commercial invoice, packing list, certificate of origin, test certificates and the import conformity certificate where Ethiopia requires one.
FAQ

Questions

Frequently asked.

How long does delivery of ACSR Conductors to Ethiopia take?
Manufacturing time depends on the rating and quantity and is confirmed with the quotation; shipping is 8 to 12 days to Djibouti, 3 to 5 days road via Djibouti (Doraleh), then road. Inspection before dispatch can be arranged for your representative or a third-party agency.
What documents and certificates come with a consignment to Ethiopia?
Commercial invoice, packing list, certificate of origin, routine test certificates per unit or drum, and the import conformity paperwork: ECAE Pre-Export Verification of Conformity: Certificate of Conformity valid six months, issued by an ECAE-authorised body; local inspection and testing for uncertified consignments.
Which standard and voltage class do you build to for Ethiopia?
IEC 60076 and related IEC standards for 50 Hz, with 15 kV and 33 kV distribution (EEU reports over 54,000 km of 15/33 kV lines), or the Ethiopian Electric Utility (EEU) for distribution and Ethiopian Electric Power (EEP) for generation and transmission specification where one is issued. Indian Standard designs with IEC equivalents are also accepted on many schemes.

Send us your ACSR Conductors schedule for Ethiopia.