Supply · Kenya
Distribution Transformers in Kenya
16 kVA – 1000 kVA. Manufactured in India to IS and IEC standards and shipped to Kenya: Ex Factory or FOB Mundra / Nhava Sheva; CIF Mombasa on request.

Finished distribution transformers in the dispatch yard
Logistics and network
Shipping to Kenya.
Consignments for Kenya move Sea from Mundra or Nhava Sheva to Mombasa, then road or rail (SGR) to Nairobi. Typical transit is 10 to 14 days; discharge at Mombasa. We quote Ex Factory or FOB Mundra / Nhava Sheva; CIF Mombasa on request, with payment by LC at sight or advance, USD.
The grid runs at 50 Hz with 415/240 V low-voltage supply and 11 kV and 33 kV distribution; 66 kV and 132 kV sub-transmission. Distribution is operated by Kenya Power (KPLC) and KETRACO for transmission, regulated by Energy and Petroleum Regulatory Authority (EPRA). Import conformity: KEBS Pre-Export Verification of Conformity (PVoC): Certificate of Conformity before shipment (Route A, B or C); destination inspection at Mombasa otherwise.
Distribution transformers are the highest-volume line on the campus — around 900 jobs a month across the full IS 1180 rating ladder, from 16 kVA agricultural units to 1000 kVA industrial supply.
Standard build is Dyn11, ONAN, 11/0.433 kV or 33/0.433 kV, with off-circuit tapping. But almost nothing here is fixed: vector group, impedance, tapping range, winding material, fittings and efficiency level are all specified by the purchaser, and we build to that schedule rather than asking you to accept ours.
| Parameter | Specification |
|---|---|
| Rated capacity | 16 kVA to 1000 kVA (1 MVA) |
| Phases | Three-phase and single-phase |
| Type | Oil-immersed, outdoor — sealed corrugated-tank or conservator type; dry type (AN) for indoor duty |
| Voltage class | 11 kV, 22 kV and 33 kV systems |
| Standard voltage ratios | 11 / 0.433 kV · 22 / 0.433 kV · 33 / 0.433 kV · 11 / 0.25 kV single-phase |
| Frequency | 50 Hz standard; 60 Hz for export |
Specifying
What changes for Kenya.
- Climate and site: Coastal humid at Mombasa; Nairobi and the highlands at 1,500 to 2,100 m, altitude derating applies.
- Built to IEC 60076 for 50 Hz, with insulation levels for the 11 kV and 33 kV distribution and 415/240 V secondaries; temperature-rise limits and cooling sized for the stated ambient and altitude.
- Fittings, bushings and tap-changer ranges follow the utility specification (Kenya Power (KPLC) and KETRACO for transmission); type-test certificates from CPRI or ERDA accompany the offer.
- Documentation: commercial invoice, packing list, certificate of origin, test certificates and the import conformity certificate where Kenya requires one.
Questions
Frequently asked.
How long does delivery of Distribution Transformers to Kenya take?
What documents and certificates come with a consignment to Kenya?
Which standard and voltage class do you build to for Kenya?
Send us your Distribution Transformers schedule for Kenya.
Ratings, quantities, the specification you are buying against and the delivery point. We return a quotation with a firm delivery programme.