Supply · Kenya
Solar & Inverter Duty Transformers in Kenya
Up to 20 MVA. Manufactured in India to IS and IEC standards and shipped to Kenya: Ex Factory or FOB Mundra / Nhava Sheva; CIF Mombasa on request.

Tanks awaiting core-and-coil assembly
Logistics and network
Shipping to Kenya.
Consignments for Kenya move Sea from Mundra or Nhava Sheva to Mombasa, then road or rail (SGR) to Nairobi. Typical transit is 10 to 14 days; discharge at Mombasa. We quote Ex Factory or FOB Mundra / Nhava Sheva; CIF Mombasa on request, with payment by LC at sight or advance, USD.
The grid runs at 50 Hz with 415/240 V low-voltage supply and 11 kV and 33 kV distribution; 66 kV and 132 kV sub-transmission. Distribution is operated by Kenya Power (KPLC) and KETRACO for transmission, regulated by Energy and Petroleum Regulatory Authority (EPRA). Import conformity: KEBS Pre-Export Verification of Conformity (PVoC): Certificate of Conformity before shipment (Route A, B or C); destination inspection at Mombasa otherwise.
The product
A solar transformer is not a distribution transformer with a different label.
An inverter feeds the transformer a non-sinusoidal current with significant harmonic content, and it does so on a duty cycle that is de-energised for roughly half the year. Both facts change the design.
Harmonic currents drive eddy-current heating in the windings that a standard design does not allow for, so conductors are transposed and the core flux density is de-rated to leave headroom. The overnight de-energised period means no-load loss dominates lifetime energy cost far more than it does on a distribution feeder — which is why the low-no-load-loss design is worth paying for here and not always elsewhere.
| Parameter | Specification |
|---|---|
| Rated power | Up to 20 MVA |
| HV voltage | 11 kV or 33 kV |
| LV voltage | 315 / 380 / 415 / 480 / 600 / 690 / 800 V — the inverter output, not 433 V |
| Winding arrangement | Two, three or more secondaries; dual secondary is the norm |
| Duty | Step-up, outdoor, solar or wind generation |
| Frequency | 50 Hz standard; 60 Hz for export |
Specifying
What changes for Kenya.
- Climate and site: Coastal humid at Mombasa; Nairobi and the highlands at 1,500 to 2,100 m, altitude derating applies.
- Built to IEC 60076 for 50 Hz, with insulation levels for the 11 kV and 33 kV distribution and 415/240 V secondaries; temperature-rise limits and cooling sized for the stated ambient and altitude.
- Fittings, bushings and tap-changer ranges follow the utility specification (Kenya Power (KPLC) and KETRACO for transmission); type-test certificates from CPRI or ERDA accompany the offer.
- Documentation: commercial invoice, packing list, certificate of origin, test certificates and the import conformity certificate where Kenya requires one.
Questions
Frequently asked.
How long does delivery of Solar & Inverter Duty Transformers to Kenya take?
What documents and certificates come with a consignment to Kenya?
Which standard and voltage class do you build to for Kenya?
Send us your Solar & Inverter Duty Transformers schedule for Kenya.
Ratings, quantities, the specification you are buying against and the delivery point. We return a quotation with a firm delivery programme.