Supply · Nigeria
Distribution Transformers in Nigeria
16 kVA – 1000 kVA. Manufactured in India to IS and IEC standards and shipped to Nigeria: Ex Factory or FOB Mundra / Nhava Sheva.

Finished distribution transformers in the dispatch yard
Logistics and network
Shipping to Nigeria.
Consignments for Nigeria move Sea from Nhava Sheva or Mundra to Lagos (Apapa or Tin Can Island), then road. Typical transit is 25 to 35 days; discharge at Lagos: Apapa / Tin Can Island; Onne for the Niger Delta. We quote Ex Factory or FOB Mundra / Nhava Sheva, with payment by LC at sight or advance, USD.
The grid runs at 50 Hz with 415/240 V low-voltage supply and 11 kV and 33 kV distribution (grid code nominal levels 330, 132, 66, 33 and 11 kV). Distribution is operated by Transmission Company of Nigeria (TCN) and the eleven DisCos (Ikeja, Eko, Abuja, Kano, Port Harcourt and others), regulated by Nigerian Electricity Regulatory Commission (NERC); NEMSA for installation safety. Import conformity: SONCAP: a Product Certificate (PC) and a SONCAP Certificate (SC) issued by a SON-appointed agency before shipment, presented at the port; transformers are a stated SON testing focus.
Distribution transformers are the highest-volume line on the campus — around 900 jobs a month across the full IS 1180 rating ladder, from 16 kVA agricultural units to 1000 kVA industrial supply.
Standard build is Dyn11, ONAN, 11/0.433 kV or 33/0.433 kV, with off-circuit tapping. But almost nothing here is fixed: vector group, impedance, tapping range, winding material, fittings and efficiency level are all specified by the purchaser, and we build to that schedule rather than asking you to accept ours.
| Parameter | Specification |
|---|---|
| Rated capacity | 16 kVA to 1000 kVA (1 MVA) |
| Phases | Three-phase and single-phase |
| Type | Oil-immersed, outdoor — sealed corrugated-tank or conservator type; dry type (AN) for indoor duty |
| Voltage class | 11 kV, 22 kV and 33 kV systems |
| Standard voltage ratios | 11 / 0.433 kV · 22 / 0.433 kV · 33 / 0.433 kV · 11 / 0.25 kV single-phase |
| Frequency | 50 Hz standard; 60 Hz for export |
Specifying
What changes for Nigeria.
- Climate and site: Hot humid coast (Lagos, Port Harcourt) with heavy corrosion exposure; dry Sahel north (Kano) with dust and 45 °C ambient.
- Built to IEC 60076 for 50 Hz, with insulation levels for the 11 kV and 33 kV distribution (grid code nominal levels 330, 132, 66, 33 and 11 kV) and 415/240 V secondaries; temperature-rise limits and cooling sized for the stated ambient and altitude.
- Fittings, bushings and tap-changer ranges follow the utility specification (Transmission Company of Nigeria (TCN) and the eleven DisCos (Ikeja, Eko, Abuja, Kano, Port Harcourt and others)); type-test certificates from CPRI or ERDA accompany the offer.
- Documentation: commercial invoice, packing list, certificate of origin, test certificates and the import conformity certificate where Nigeria requires one.
Questions
Frequently asked.
How long does delivery of Distribution Transformers to Nigeria take?
What documents and certificates come with a consignment to Nigeria?
Which standard and voltage class do you build to for Nigeria?
Send us your Distribution Transformers schedule for Nigeria.
Ratings, quantities, the specification you are buying against and the delivery point. We return a quotation with a firm delivery programme.