Power Transformers in Tanzania

1 – 20 MVA. Manufactured in India to IS and IEC standards and shipped to Tanzania: Ex Factory or FOB Mundra / Nhava Sheva; CIF Dar es Salaam on request.

Range1 – 20 MVA
Delivery12 to 16 days
Standard1 – 20 MVA
Power transformer under assembly

Power transformer under assembly

01

Logistics and network

Shipping to Tanzania.

Consignments for Tanzania move Sea from Mundra or Nhava Sheva to Dar es Salaam, then road inland. Typical transit is 12 to 16 days; discharge at Dar es Salaam. We quote Ex Factory or FOB Mundra / Nhava Sheva; CIF Dar es Salaam on request, with payment by LC at sight or advance, USD.

The grid runs at 50 Hz with 400/230 V low-voltage supply and 11 kV and 33 kV distribution; 132 kV, 220 kV and 400 kV transmission. Distribution is operated by Tanzania Electric Supply Company (TANESCO), regulated by Energy and Water Utilities Regulatory Authority (EWURA). Import conformity: TBS Pre-Export Verification of Conformity (PVoC): consignment-based Certificate of Conformity valid three months, issued by Intertek, SGS or TUV Rheinland under the 2025-2028 contract.

02

The product

Power-class capability, in-house.

Full specification and gallery

The power transformer line closed the last gap in the chain. Between distribution and power class we now cover 16 kVA right through to 20 MVA — a span very few regional manufacturers hold on a single site.

The standard substation build is 33/11 kV, Dyn11, ONAN, with an off-circuit tap changer at +5% to −10%. Where the network needs voltage regulation under load we fit an on-load tap changer at +5% to −15%, and where the load profile justifies forced cooling we supply ONAF with a rated output at each cooling stage.

ParameterSpecification
Rated power1 MVA to 20 MVA
Typical ratings1 · 1.6 · 2 · 2.5 · 3.15 · 5 · 6.3 · 8 · 10 · 12.5 · 16 · 20 MVA
Voltage class33 / 11 kV; highest system voltage 36 kV
PhasesThree-phase
TypeOil-immersed, outdoor, core type — plain or corrugated tank; dry type to order
Frequency50 Hz standard; 60 Hz for export
03

Specifying

What changes for Tanzania.

  • Climate and site: Humid coast at Dar es Salaam; dry plateau inland at 1,000 to 1,500 m (Dodoma, Arusha, Mbeya).
  • Built to IEC 60076 for 50 Hz, with insulation levels for the 11 kV and 33 kV distribution and 400/230 V secondaries; temperature-rise limits and cooling sized for the stated ambient and altitude.
  • Fittings, bushings and tap-changer ranges follow the utility specification (Tanzania Electric Supply Company (TANESCO)); type-test certificates from CPRI or ERDA accompany the offer.
  • Documentation: commercial invoice, packing list, certificate of origin, test certificates and the import conformity certificate where Tanzania requires one.
FAQ

Questions

Frequently asked.

How long does delivery of Power Transformers to Tanzania take?
Manufacturing time depends on the rating and quantity and is confirmed with the quotation; shipping is 12 to 16 days via Dar es Salaam. Inspection before dispatch can be arranged for your representative or a third-party agency.
What documents and certificates come with a consignment to Tanzania?
Commercial invoice, packing list, certificate of origin, routine test certificates per unit or drum, and the import conformity paperwork: TBS Pre-Export Verification of Conformity (PVoC): consignment-based Certificate of Conformity valid three months, issued by Intertek, SGS or TUV Rheinland under the 2025-2028 contract.
Which standard and voltage class do you build to for Tanzania?
IEC 60076 and related IEC standards for 50 Hz, with 11 kV and 33 kV distribution, or the Tanzania Electric Supply Company (TANESCO) specification where one is issued. Indian Standard designs with IEC equivalents are also accepted on many schemes.

Send us your Power Transformers schedule for Tanzania.

Ratings, quantities, the specification you are buying against and the delivery point. We return a quotation with a firm delivery programme.